Fluorescent additive for locating leaks in R134a air-conditioning systems without an air conditioning service unit.

Air-conditioning service unit not required to perform a service


Portable

Notice

If the special filling adapter is mounted, no pressure is displayed on the service unit manometer. Remove the adapter to measure the high pressure. Adapter art. no. 0764000111 and art. no. 0764000112 can only be used with a 134a coupling.

Application area
  • Remove one screw cap and screw the free end of the leak detection additive to the filling adapter, art. no. 0764000111

  • Remove the second screw cap and screw on intermediate adapter, art. no. 0764000112
  • Connect the fully assembled special R134a filling adapter to the high-pressure side
  • Connect the R134a quick-action coupling on the service unit to the free end of the special R134a filling adapter
  • Fill the air-conditioning unit with the appropriate amount of refrigerant. The additive is then flushed into the air-conditioning unit

The usage instructions are recommendations based on the tests we have conducted and our experience. Carry out your own tests before each application. Due to the large number of applications as well as storage and usage conditions, we do not assume any liability for a specific application result. Any technical information or advice provided by our free customer service shall be provided to the exclusion of any liability, unless the advice or information is part of our contractually agreed scope of services or the advisor was acting wilfully. We ensure the consistent quality of our products. We reserve the right to make technical changes and further developments to our products.

Product information

Datasheets(X)

Certificates/ Documents

 | 

 | 

Application area

For reliable localisation of leaks and micro-leaks in R134a air-conditioning systems. Can be used in air-conditioning systems with electric compressors (hybrid, start/stop, electric vehicles).

Instructions

Remove one sealing cap and screw the free end of the leak detection additive to the filling adapter
Remove the second sealing cap and screw onto the intermediate adapter
Connect the fully assembled special R134a filling adapter to the high-pressure side
Connect the R134a quick-release coupling on the service unit to the free end of the special R134a filling adapter
Fill the air-conditioning unit with the corresponding amount of refrigerant. The additive is then flushed into the air-conditioning unit

Contents

1.8 ml

Chemical basis

Synthetic oil

Colour

Yellow

Smell/fragrance

Aromatic

Density

0.97 g/cm³

Shelf life from production

48 Month

Min. flashing point

88 °C

Water-soluble

No

Viscosity/consistency

Liquid

Boiling point

217 °C

Suitable glove:
 
Product
Description
Chemical cut protection glove W-310 Level D
Chemical cut protection glove W-310 Level D
Description:
Permeation level: 6
Very robust, liquid-proof protective glove that combines optimal cut protection with chemical protection
Vinyl chemical and moisture protective glove
Vinyl chemical and moisture protective glove
Description:
Permeation level: 6
Fully dipped protective glove with vinyl coating on cotton jersey lining
Chemical protective glove, Butyl
Chemical protective glove, Butyl
Description:
Permeation level: 6
Gas-tight and resistant to exhaust gases produced by combustion processes
Nitrile chemical protective glove
Nitrile chemical protective glove
Description:
Permeation level: 6
With cotton velour finish inside.
Disposable nitrile glove
Disposable nitrile glove
Description:
Permeation level: 2
Liquid-proof, food-safe disposable glove
Disposable nitrile grip glove
Disposable nitrile grip glove
Description:
Permeation level: 2
Unique, diamond texture for optimal grip
Disposable glove Nitrile Grip Comfort
Disposable glove Nitrile Grip Comfort
Description:
Permeation level: 3
Very robust disposable gloves with excellent grip thanks to special nubs and maximum wearing comfort thanks to cotton flocking inside
Disposable gloves, nitrile, extra strong, type A
Disposable gloves, nitrile, extra strong, type A
Description:
Permeation level: 4
Durable and robust disposable gloves with excellent chemical protection
Permeation is the process by which a chemical moves through the material of a protective glove on a molecular level. The time from the initial contact between the chemical and the glove to the permeation of the material is the breakthrough time.
Measured breakthrough time
Permeation level
< 10 min
0
≥ 10 min
1
≥ 30 min
2
≥ 60 min
3
≥ 120 min
4
≥ 240 min
5
≥ 480 min
6

Important information:

The information given is based on experience and laboratory conditions and is designed as a guide. However, the actual suitability of a glove depends on the individual conditions of its use and must be confirmed by an appropriate test under operational conditions. Given the variety of materials and chemicals used, the possibility of incompatibility or usage problems for the wearer cannot be excluded in individual cases. We would be happy to advise you about optimum solutions.

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 